3. After window is completely dry, apply a good-
quality floor wax with a poly base. This will fill
in any scratches and restore the clarity of the
window.
To avoid cracking the bubble window, always use
the latches on the inside of the cab to close the win-
dow. Do not apply force to the window itself.
LUBRICATION
AUTOMATIC LUBRICATION
If the sweeper is equipped with the optional auto-
matic lubrication system, the system and the bear-
ings it serves should be inspected periodically as
recommended in the manual from the system man-
ufacturer.
TORQUE HUB OIL
Oil level and type may vary with specific torque
hub model and application.
Type
SAE 80W-90
On applications where the lubricant must meet
special requirements, a suitable substitute may be
used. Contact Elgin Sweeper Company regarding
special lubrication needs.
Oil Temperature
Continuous - 160°F (70°C)
Intermittent - 200°F (95°C)
Oil Change Schedule
Initial - After 50 hours of operation
Subsequent - After 1000 hours or one year,
whichever comes first.